Cadex C8000 may well be the most complete and affordable enterprise battery testing system available today.
The Cadex C8000 reads SMBus batteries to verify fuel gauge settings, provide calibration, do performance check and assist in troubleshooting.
C8000 allows testing batteries under GSM, CDMA and other digital protocols. Programming is in 50µs intervals with minimum setting of 500µs.
Application: Dynamic stress tests to examine battery runtime under digital load conditions.
C8000 tests batteries by continuously cycling to end-of-life. BatteryLab™ records the test results in real time.
Application: Life-test until the capacity drops to the Target Selector red-line.
Charge-discharge-charge; applies Recondition on nickel-based batteries if user-set target capacity cannot be reached.
Applies fast charge with charge termination; trickle when applicable.
Prepares batteries by cycling until the maximum capacity is reached. The first reading is the spare capacity before charge.
Activates batteries that have been discharged too low.
Extended Prime: 16-hour trickle charge, then automatically move to Prime.
Tests batteries under simulated GSM, CDMA and other discharge protocols, 50μs steps; minimum setting 500μs.
Provides three discharge levels; programmable in hours and minutes.
Cycles battery until the capacity fades the set Target Selector threshold.
Determines the rate at which a battery loses charge. Assure intrinsic safety.
Prepares battery for shipping and storage. Also checks charger function.
Simulates real life conditions with pre-recorded load. Requires PC-BatteryLab™ and Load Capture Unit to record load signature.
Measure battery resistance with DC pulses in 13 seconds; based on IEC61436.
Measures battery resistance with 1000Hz signal. Channel 1 only.
Each channel features a Battery Port and I/O Port for individual programming with:
Positive/negative input; 4-wire Kelvin
1 analogue thermistor input
4 differential analogue voltage inputs
2 analogue outputs
4 input/output control for switching
SMBus, clock, data for smart packs
Transform your C8000 into an automated command centre running external accessories:
Cell monitoring
Heating element
Pressure gauge
Safety circuit
Alarms (with custom programs using BatteryLab)
Serving as a laboratory command centre.
One of the four channels supports the load bank.
For safety, reasons, load bank service is limited to discharge only.
The Dual Power Port Cable (DPPC) allows parallel connection of channels 1 and 2, or 3 and 4, to increase current from 10A to 20A.
Limitation: DPPC only applies to discharge.
Included: 1x DPPC Included
Floating analogue inputs enable voltage check of up to 5 cells